PRPMA4100 PV Soiling Sensor

The PRPMA4100 measures the soiling ratio of PV arrays using Mars optical imaging technology: a camera periodically photographs a particle-collection window and image analysis converts the deposited dust into a transmission loss. Because it does not rely on a reference cell, it needs no site-specific calibration and very little maintenance. Mounted at the same orientation as the modules and washed on the same schedule, it tracks the losses the plant actually experiences.
  • Image-based optical measurement of soiling loss with 1% accuracy
  • No site-specific calibration or clean reference module required
  • Modbus RTU over RS485 for direct connection to Alpha-Log or plant SCADA
  • Low maintenance; wash alongside the PV modules
  • IP67 housing rated for -20 to 60 C
  • Low power: under 3 W average from 10-30 V DC
  • Supports washing optimisation, soiling-rate forecasting and site prospecting
Measured quantityTransmission loss due to soiling
TechnologyOptical (Mars imaging)
Accuracy+/-1%
CalibrationNo local calibration required
OutputModbus RTU (RS485)
Power supply10-30 V DC
Consumptionunder 3 W average, under 6 W peak
Operating temperature-20 to 60 C
Size / weight115 x 115 x 98 mm, 1.48 kg
ProtectionIP67
  • Utility-scale PV plant performance monitoring
  • Optimising module cleaning schedules
  • Pre-construction soiling assessment of new sites
  • Solar resource and yield modelling