The ETG 7500 is a shipboard continuous emissions monitoring system built to prove compliance with international sulphur regulations. One central analysis unit serves multiple sampling points, each with its own probe and local control unit, drawing exhaust through heated lines and ceramic filters to cope with high temperatures and soot. Materials and design are chosen for the marine environment, and a built-in backup keeps measurement running if a component fails.
- Certified by RINA and IACS for onboard installation
- CO2 measured by NDIR and SO2 by UV-DOAS, with live SO2/CO2 ratio
- Multi-point sampling with heated lines and high-temperature ceramic probe filters
- Corrosion-resistant construction for marine conditions
- Automatic backup maintains analysis after a first failure
- Automatic calibration and easy-access maintenance
- Operator panel viewable remotely on any PC, including the control room
- Modbus, Profibus, Profinet and 4-20 mA outputs
| Measured gases | CO2 (%), SO2 (ppm), SO2/CO2 ratio |
| CO2 sensor | NDIR infrared |
| SO2 sensor | UV-DOAS |
| Sampling | Heated sample line, ceramic probe-head filter, multi-stage cleaning |
| Outputs | Modbus, Profibus, Profinet, 4-20 mA |
| Calibration | Automatic |
| Redundancy | Automatic backup |
| Certifications | RINA, IACS; MARPOL Annex VI compliance monitoring |
- Marine exhaust emissions monitoring
- Scrubber performance verification
- MARPOL sulphur compliance reporting
- Multi-boiler and multi-engine vessels
Datasheet / brochure not available to download at the moment – to be added by the developer.