The Class C range provides dependable global irradiance measurement where a secondary standard is not required, such as basic meteorological stations, agro-meteorology and smaller solar installations. The DPA053A is a passive sensor supplied with a 5 m cable and calibration certificate, the DPA863 adds a 4-20 mA transmitter, and the DPA983 offers a galvanically isolated RS485 Modbus interface with programmable statistics. All share the same anodised aluminium IP66 body.
- ISO 9060:2018 Class C; WMO moderate-quality level; IEC 61724-1 Class C
- Daily uncertainty 10% with 285-3000 nm spectral range
- DPA053A microvolt output with 5 m cable and calibration certificate included
- DPA863 4-20 mA and DPA983 RS485 Modbus RTU / TTY-ASCII with 10-30 V AC/DC supply
- DPA983 delivers instant, minimum, maximum and average values over a programmable period
- Non-linearity 1% between 100 and 1000 W/m2
- IP66 anodised aluminium housing with radiation shield
- Calibration traceable to the WRR; recalibrate every two years
| ISO 9060:2018 class | Class C (second class) |
| Accuracy (daily sums) | +/-10% |
| Spectral range | 285-3000 nm |
| Irradiance range | 0-2000 W/m2; 0-1500 W/m2 output span (DPA863, DPA983) |
| Output | 10-15 uV/W/m2 (DPA053A); 4-20 mA (DPA863); RS485 Modbus (DPA983) |
| Power supply | 10-30 V AC/DC, 0.5 W (DPA863, DPA983) |
| Temperature response | under 7% (-10 to 40 C) |
| Operating temperature | -40 to 80 C |
| Protection | IP66 |
| Cable | 5 m included (DPA053A); sold separately (DPA863, DPA983) |
- Basic meteorological and agro-meteorological stations
- Small and medium PV plant monitoring
- Irrigation and evapotranspiration calculation
- Education and environmental studies