LSI LASTEM offers three visibility sensors. The DPA320 is a cost-effective forward-scatter unit for visibility only, the DPA305 adds present-weather detection, an analogue output and three relays for driving warning signs, and the DPA311.1 is a back-scatter sensor with compressed-air lens cleaning intended for tunnels and heavily polluted sites. All are supplied with a pole-mounting kit and connect directly to LSI data loggers.
- Three models: DPA320 (visibility), DPA305 (visibility, present weather and relays) and DPA311.1 (back-scatter with self-cleaning optics)
- Default range 10 m to 2 km, selectable up to 75 km on the DPA305 and 7.5 km on the DPA320
- Present-weather models report precipitation type (WMO code 4680), intensity and accumulation
- DPA305 provides 4-20 mA, RS232/422/485 and three relay outputs for fault, visibility threshold and precipitation alarms
- DPA311.1 keeps its lenses clean with a 0.6 bar compressed-air system
- Operation down to -40 C in IP66 or IP67 housings
- Compatible with E-Log and Alpha-Log data loggers
| Principle | Forward scatter 45 deg (DPA305, DPA320); back scatter (DPA311.1) |
| Visibility range (default) | 10 m to 2 km |
| Extended range | Up to 75 km (DPA305); 7.5 km (DPA320, DPA311.1) |
| Resolution | 1 m or 10 m |
| Precipitation intensity | 0-60 mm/h, +/-20% (DPA305, DPA311.1) |
| Outputs | 4-20 mA, RS232/422/485, 3 relays (DPA305); RS232/485 (DPA311.1, DPA320) |
| Power supply | 9-36 V DC (DPA305, DPA320); 11-24 V DC (DPA311.1) |
| Consumption | 2-3.5 W, up to 6 W with heater |
| Operating temperature | -40 to 60 C (DPA305, DPA320); -40 to 85 C (DPA311.1) |
| Protection / weight | IP66, 4.2-4.3 kg (DPA305, DPA320); IP67, 8 kg (DPA311.1) |
- Road and motorway fog warning
- Tunnel portal monitoring
- Airports and heliports
- Ports and railways
- Intelligent transport systems