Standard 3-Cup Anemometer (DNA301 / DNA801 series)

LSI LASTEM’s standard cup anemometers are built for accurate measurement at very low wind speeds, using a 32-step optoelectronic disc that gives 0.06 m/s resolution and a 0.26 m/s starting threshold. Frequency-output models connect directly to LSI loggers, while the analogue versions use a microprocessor to linearise the 4-20 mA, 0-20 mA or 0-5 V signal across the range. Heated models keep the bearings free of ice down to -20 °C.
  • Low starting threshold (0.26 m/s) and 0.06 m/s resolution
  • Accuracy ±0.25 m/s or 3 % below 25 m/s, 2 % above
  • Frequency output (13 Hz per m/s) or linearised analogue output
  • Wide 10-30 V AC/DC supply on analogue models
  • Heated versions (DNA302.1, DNA802, DNA806) for icy conditions
  • Low-power version for energy-limited sites
  • Anodised aluminium housing, IP66, survives 75 m/s
  • Cable lengths up to 100 m; ISO/IEC 17025-accredited calibration
ModelsDNA301.1, DNA302.1 (frequency); DNA801, DNA801.1, DNA802, DNA805, DNA806, DNA807 (analogue)
Measuring range0 to 50 m/s (DNA801.1: 0-60 m/s); 75 m/s damage limit
Accuracy±0.25 m/s or 3 % (0-25 m/s); 2 % (> 25 m/s)
Threshold / resolution0.26 m/s / 0.06 m/s
Delay distance4.8 m at 10 m/s (VDI 3786, ASTM 5096-96)
Outputs0-883 Hz (DNA301.1/302.1); 4-20 mA, 0-20 mA or 0-5 V DC (DNA80x)
Power supply10 to 30 V AC/DC, max 0.5 W; heater 24 V AC, 20 W
Operating temperature-40 to +70 °C (without ice)
ProtectionIP66; 7-pin IP65 connector
MountingMast Ø 48-50 mm
  • Professional weather stations
  • Wind resource assessment
  • Airports and road weather
  • Hydrology and reservoir monitoring
  • Waste and landfill sites