ETG 6900 – TDL

The ETG 6900 uses tunable diode laser spectroscopy to lock onto the absorption line of a single target gas with a bandwidth of around 0.1 nm, giving high resolution and very little cross-interference from other compounds. It measures continuously in real time down to low ppm levels and, because the laser technique is inherently stable, needs far less frequent calibration than conventional sensors. The same core is offered in fixed and portable housings.
  • Tunable diode laser (TDL) measurement with roughly 0.1 nm bandwidth
  • High resolution with minimal interference from background gases
  • Reliable low-ppm detection in continuous, real-time operation
  • Reduced calibration frequency lowers lifetime cost
  • Single-gas or multi-gas configurations
  • Wall-mounted, 19-inch rack or portable formats
  • Fixed and mobile heated sample lines and probes for hot gas analysis
  • Supports most common communication protocols
  •  
TechnologyTunable diode laser spectroscopy (TDL)
Laser bandwidthApprox. 0.1 nm
Measured gasesCH4, CO2 (ppm), HCl (ppm), NH3 (ppm)
ConfigurationSingle compound or several simultaneously
FormatsWall-mounted, 19-inch rack, portable
AccessoriesHeated sample lines and sampling probes
CommunicationMost industrial protocols supported
  • Ammonia slip monitoring downstream of SCR deNOx systems
  • Methane emissions from landfills and biogas plants
  • Greenhouse gas monitoring
  • HCl monitoring in industrial emissions
  • Fenceline and environmental monitoring
  •