A portable source of ozone that is the perfect companion for calibrating virtually any ambient ozone analyzer – The instrument scrubs ozone from ambient air and produces any mixing ratio of ozone in the range 30 to 1,000 ppbv.

Traditional gas-phase titration (GPT) calibrator that can produce ambient concentrations of ozone, NO, and NO2 used to calibrate ambient ozone and NOx analyzers.

MesaLabs Defender Series are the industry standard for accurate, reliable and portable Primary calibrators. DefenderTM Series are backed by Proven DryCal® technology and have a reading uncertainty of less than 1%. 3 models for 3 flow standards: 510, 520, 530+

Mesa Labs’ newest standardized and volumetric primary flow standard offers easy-to-navigate calibrations with unparalleled flow ranges, accuracy and portability. The FlexCal offers flow ranges up to 50 LPM with a standardized accuracy of 0.5%, but is small, easy to carry and ready for even the most demanding of applications. When you use Mesa Labs’ FlexCal, you are guaranteed high accuracy with high confidence without the use of soap bubbles, timers, or heavy provers.

The DryCal 800 is a positive displacement primary piston prover for gas flow measurements in either pressure or vacuum applications. It combines the accuracy of a primary standard with unequalled speed and convenience. It meets the most stringent laboratory and industrial process control requirements, making it an ideal solution.

Primary Flow Calibration Standard for High Capacity Gas Flow. This powerful calibrator, featuring patented proven DryCal® Technology is changing the game of flow calibration. The instrument has a range of from 5 to 1500 standard liters per minute (slpm) – more than ten times the volume of any other piston prover on the market! The portability and the innovative benchtop design is a welcome change from over bell provers systems

The BGI tetraCal® is a simple-to-use standard for volumetric airflow, barometric pressure, and ambient temperature. Venturi based system with built-in compensation for changes in ambient temperature and pressure.

The BGI deltaCal® is a simple-to-use, NIST Traceable Standard for volumetric air flow, barometric pressure, and ambient temperature. Venturi based system with built-in compensation for for calibration of PM2.5 and PM10 samplers in accordance with US EPA requirements

The Model 4010M is a simple, but powerful Intelligent Multi-gas Dilution Calibrator that can easily perform gas dilution, multi-source gas blending, ozone generation, and gas phase titration (GPT = NO + O3 => NO2) for environmental, laboratory, or point source monitoring.

A simple but powerful Intelligent Multi-gas Dilution Calibrator that can easily perform gas dilution, multi-source gas blending, ozone generation, and gas phase titration (GPT = NO + O3 => NO2) for environmental, laboratory, or point source monitoring Calibrator

The Model 2010 is a simple, but powerful Intelligent Multi-gas Dilution Calibrator that can easily perform gas dilution, multi-source gas blending, ozone generation, and gas phase titration (GPT = NO + O3 => NO2) for environmental, laboratory, or point source monitoring.

The Model 4010T is a simple, but powerful Intelligent Multi-gas Dilution Calibrator that can easily perform gas dilution, multi-source gas blending, ozone generation, and gas phase titration (GPT = NO + O3 => NO2) for environmental, laboratory, or point source monitoring.

The Model 2010T is a simple, but powerful Intelligent Multi-gas Dilution Calibrator that can easily perform gas dilution, multi-source gas blending, ozone generation, and gas phase titration (GPT = NO + O3 => NO2) for environmental, laboratory, or point source monitoring.

The Model 6030 Ozone Transfer Standard is NIST traceable and provides an accurate and convenient means of measuring low levels of ozone in ambient air

The Model 2030 Portable Ozone Transfer provides an accurate and convenient means of measuring low levels of ozone in ambient air.

Model 306 Ozone Calibration Source
A portable source of ozone that is the perfect companion for calibrating virtually any ambient ozone analyzer – not just those manufactured by 2B Tech. The instrument scrubs ozone from ambient air and produces any mixing ratio of ozone in the range 30 to 1,000 ppbv.
- Ozone mixing ratio controlled so as to be independent of ambient temperature, pressure and humidity
- Level 4 transfer standard for calibrating ozone analyzers in the field relative to a lab standard
- Schedule an autocalibration once daily that executes a series of up to 10 programmable output steps

Overview
- Portable ozone calibration source that produces O3 by photolysis of O2 in air at 185 nm
- Desired ozone concentration in the range of 30 to 1000 ppbv is chosen from the easy-to-use menu using a rotary select switch, or can be controlled remotely via the serial menu
- Total output flow rate in the range 3.0-3.2 L/min volumetric and can be connected directly to the inlet of any ozone analyzer
- Excess flow is vented through an internal overflow T capped with an ozone scrubber
- Factory-calibrated against 2B Tech’s NIST-traceable standard Can easily be calibrated against your lab ozone standard, allowing the instrument to be a transfer standard for calibrating ozone instruments in the field
- Scheduler function allows a scheduled autocalibration once daily that executes a series of up to 10 programmable output steps
- Please see our published paper for more information about the Model 306