cGas Detector Ammonia Vent Line Transmitter

  • Single channel, internal catalytic Ammonia sensor
  • 4-20 mA analog output or user configurable in the field, BACnet® MS/TP (version 1 rev 14) RS-485 or Modbus® RTU (version 1.1b3) RS-485
  • 24 VDC or VAC power (ground referenced)
  • Easy Plug & Play Smart Sensor replacement at end of life, comes pre-calibrated
  • Bright LCD display
  • USB port for configuration changes and firmware upgrades
  • Optional 2A SPDT dry contact relay (Option -RLY)
  • Optional low temperature operation package (Option -LT)
  • Standard water / dust tight, corrosion resistant enclosure (drip proof)
  • Thermal resetting fuses
  • RoHS compliant circuit board

Gas Sensor:  Ammonia (NH3), measurement range 0 – 3.00% volume 

Tolerant to 17% volume. NOTE: Ammonia is flammable between 15% (LEL) and 28% (UEL) volume in air.

Type:  Catalytic

Response Time T90:  30 seconds

Enclosure:  Black ABS / Polycarbonate, copper coated interior to reduce RF interference
IP54 rated with splash guard installed

Size:  Detector with splash guard: 127 x 127 x 84 mm / 5.0 x 5.0 x 3.3 in
Completely assembled product: 127 x 127 x 182.5 mm / 5.0 x 5.0 x 7.18 in

Coupler:  19.5 mm / 3/4 inch NPT, cast steel

Sensor Assembly Length (including coupler):  98.5 mm / 3.875 inches

Display (Standard):  2-line by 16 character graphic LCD
Operating Temperature: 0°C to 40°C / 32°F to 104°F

Display (Option -LT):  2-line by 16 character OLED display and internal heater
Operating Temperature: -40°C to 40°C / -40°F to 104°F

Power Requirement:  3-wire: 16-30 VDC, 3W, Class 2
4-wire: 12-27 VAC, 50-60 Hz, 3 VA, Class 2
24V recommended

Wiring (CGAS-A-VLT model):  VDC (or ground referenced AC): 3-conductor 18 AWG (or larger) shielded, stranded within conduit
VAC 4-conductor shielded 18 AWG stranded within conduit

Wiring (CGAS-D-VLT Model)

VDC or VAC (ground referenced) 4-conductor shielded 16 AWG stranded within conduit, network wiring (daisy-chain)

Conforms to

CSA-C22.2 No. 205-12, UL508 (Edition 18):2018 

EMC Directive 2014/30/EU, EN 50270:2015, Type 1, EN61010 

FCC. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. 

RoHS compliant circuit boards

  • Ice Arenas
  • Refrigeration Plants
  • Cold Storage Rooms
  • Freezer Rooms
  • Ammonia Plants