Leafy

  • Real-time 5-wavelength UV-IR Black Carbon monitor
  • An outdoor-rated case with an 85 sampling location automatic filter tape advance system
  • Up to 15 months of continuous measurements.
  • The device is a self-contained instrument with built-in pump, flow control, data storage, and 4X the battery capacity of the MA200.
  • Onboard GPS, satellite time synchronization, accelerometer, altimeter/barometer, and sensors for relative humidity and temperature
  • Designed as a network node to be installed outdoors on street poles and along fence lines for extended multi-month measurement campaigns
  • The 85 location filter tape cartridge allows for extended continuous sampling of higher concentrations for up to a year depending on the sampling environment conditions and instrument settings.

Measurement Method

 Real-time Aethalometer® method, 5 wavelength absorption analysis by measuring the rate of change of transmitted light due to continuous particle deposition on filter. Measurement at 880 nm interpreted as concentration of Black Carbon (‘BC’). Measurement at 375 nm interpreted as Ultraviolet Particulate Matter (‘UVPM’) indicative of woodsmoke, tobacco, and biomass burning.

Measurement Wavelength

 880 nm, 625 nm, 528 nm, 470 nm, 375 nm

DualSpot® Loading Compensation

 Real-time analysis by measuring the rate of change in absorption of transmitted light due to the continuous collection of aerosol on filter. Simultaneous collection on two spots in parallel at different flow rates.

Timebases

 1, 5, 10, 30, 60, or 300 seconds

Flow Rates

 Internal pump provides 50, 75, 100, 125, 150 or 170 ml/min. DualSpot® compensation not compatible with all settings.

Measurement Range

 Per sampling location, 0-1 mg BC/m3, filter sampling location lifetime dependent on concentration and flow rate setting, decreasing proportionally with lowest wavelength optical source enabled:
– IR only mode, average 5 μg BC/m3 for 24 hours at 100 ml/min
– IR only mode, average 100 μg BC/m3 for 3 hours at 50 ml/min
– IR only mode, average 1 mg BC/m3 for 15 minutes at 50 ml/min

Measurement Resolution

 0.001 μg BC/m3

Limit of Detection

 30 ng BC/m3, 5 min timebase., 150 ml/min flow rate, SingleSpot™

Pump Options

 Standard internal diaphragm pump

Flow Control

 Internal mass flowmeters with closed-loop control

Filter Material / Capacity

 MA300/350 Filter Tape Cartridge with Polytetrafluoroethylene (PTFE) material (85 sampling locations)

Sampling

3 mm diameter spot(s) created on filter tape. User selectable DualSpot® or SingleSpot™ mode.

Environmental Sensors

 Accelerometer, Relative Humidity, Temperature, Altimeter/Barometer

Dimensions

 L: 199.90 mm (7.87 in), W: 99.82 mm
(3.93 in), D: 69.85 mm (2.75 in)

Weight

 965 grams (34.04 ounces)

Memory

 16 GB internal flash memory, providing storage for 31,250,000 data lines; 1 second timebase: 361 days of data.

On-board Interface

 Low power screen, 3 buttons

Location Services

 GPS with Internal Antenna

Date/Time Format

 ISO 8601 with satellite synchronization or manual computer synchronization

Wireless

802.11 b/g/n Wi-Fi with AES hardware encryption, Bluetooth Low Energy. Available in future firmware releases.

Connections

 Via external sealed connector for 3.3V TTL Serial and DC input via barrel jack, Aerosol sample inlet and outlet ports, USB 2.0 on inside panel

USB Communication / Client Application

 USB connectivity to cross-platform microAeth® Manager software available on macOS® and Windows®. microAeth Manager software is included and facilitates settings configuration and data download. Exported data can be uploaded to AethLabs Dashboard server for processing and visualization.

Serial Communication

3.3V TTL serial connectivity for uploading new instrument firmware, flow calibration, streaming data and polling protocols to request data, modify settings and control. Command line interface (CLI) polling protocols: AethLabs protocol and Bayern-Hessen protocol.

Total Run Time

 Up to 56 hours at 60 second timebase, 100 ml/min flow rate on single battery charge. Run time may vary due to PM concentrations and settings.

Battery

 Internal 3.6V 12800 mAh (46.08 Wh), 4 cell rechargeable lithium-ion battery

Charging

 Fast charging DC via barrel jack AC adapter (~11.75 hours to full charge, instrument turned off) or
USB charging (~25.75 hours to full charge, instrument turned off)
Power Supply Adapter: Input: 100~240 VAC 50/60Hz 0.4A, Output: 5VDC / 2A, with option for Type A, C, G, or I plug

Operation Environment

 5 ~ 40 °C operating, non-condensing.

Included

 microAeth MA350,
1 MA300/350 Filter Tape Cartridge,
 MA350 Sealed connector to DC barrel jack and serial port cable,
Barrel jack AC adapter with 1 territory-specific plug,
USB communication/charging cable,
2 one meter sampling hoses with swivel tube connectors.
Cross-platform microAeth® Manager software and manual available for download via AethLabs website

Accessories & Consumables

 MA300/350 Filter Tape Cartridge,
 MA Series Flow Calibration Kit,
microCyclone™ PM2.5 Size-selective Inlet,
MA350 Sealed connector to bare leads cable,
Serial to USB converter cable,
Serial to bare leads cable,
Portable Aerosol Dryer,
MA350 Pole kit

Specifications are subject to change without notice. microAeth MA Series products are protected by patent #8,411,272.
Additional patents pending. Aethalometer® and DualSpot® are trademarks of Magee Scientific Corp. used under license.

  • Continuous real-time monitoring
  • Mobile monitoring
  • Multi-month filter life
  • Exposure assessment
  • Health effects
  • Occupational safety
  • Source apportionment
  • Tobacco
  • Woodsmoke
  • Biomass
  • Ambient air monitoring
  • Stationary monitoring
  • Indoor air quality
  • Vehicle on-road mobile monitoring
  • Networks
  • Fence line monitoring
  • Near-road monitoring
  • Urban environment on street poles
  • High concentration / Cookstove monitoring